紫外可見近紅外光分光光譜儀 UV-3600Plus
❤ 收藏

紫外可見近紅外光分光光譜儀 UV-3600Plus

搭載高性能雙分光器可實現高解析度(最高0.1 nm)與超低迷光(340 nm,迷光0.0005%以下)。

 

此外測定波長範圍為185~3300 nm,可大範圍測定涵蓋紫外、可見、近紅外光領域。可對應在各領域的紫外光譜分析。

0.00
0.00
¥0.00
¥0.00
重量:0.00KG
產品描述

搭載高性能雙分光器可實現高解析度(最高0.1 nm)與超低迷光(340 nm,迷光0.0005%以下)。

 

此外測定波長範圍為185~3300 nm,可大範圍測定涵蓋紫外、可見、近紅外光領域。可對應在各領域的紫外光譜分析。


Wavelength range

185 nm - 3300 nm

Spectral band width

UV/VIS region: 0.1, 0.2, 0.5, 1, 2, 3, 5, 8 nm (8 steps)
NIR region: 0.2, 0.5, 1, 2, 3, 5, 8, 12, 20, 32 nm (10 steps)

Resolution

0.1 nm

Wavelength Sampling

0.01 to 5 nm

Wavelength accuracy

±0.2 nm in UV-VIS region, ±0.8 nm in NIR region

Wavelength repeatability

within ±0.08 nm in UV-VIS region, ±0.32 nm in NIR region

Wavelength scanning speed

When moving between wavelengths:
approx. 18000 nm/min in UV-VIS region, approx. 70000 nm/min in NIR region
When scanning wavelengths:
Max. approx 4500 nm/min in UV-VIS region, Max. approx. 9000nm/min in NIR PMT/InGaAs region, Max. approx 4000 nm/min in NIR PbS region (excluding time required for switching)

Light source switching

The light sources are switched automatically in conjunction with wavelength scanning. The wavelength at which the light sources are switched can be freely set in a range of 282 to 393 nm in 0.1 nm increments.

Stray light

Max. 0.00008% (220 nm, NaI)
Max. 0.00005% (340 nm, NaNO2)
Max. 0.0005% (1420 nm, H2O)
Max. 0.005% (2365 nm, CHCl3)

Photometric system

Double-beam

Photometric range

-6 to 6 Abs

Photometric accuracy

±0.003 Abs (1 Abs), ±0.002 Abs (0.5 Abs) determined with NIST930D standard filter

Photometric repeatability

0.0008Abs (0 to 0.5 Abs), 0.0016 Abs (0.5 to 1 Abs) determined under conditions of 1 second accumulation and maximum deviation for five times measurements.

Noise

Under 0.00005Abs (500nm), 0.00008Abs (900nm), 0.00003Abs(1500nm)
Determined under condition of Slit width 2nm, RMS value at 1 second integration.

Baseline flatness

±0.004 Abs (185 to 200 nm)
±0.001 Abs (200 to 3000 nm)
±0.005 Abs (3000 to 3300 nm)

Baseline stability

Within 0.0002 Abs/h (after 2 hour warm-up, 500nm, 1-second accumulation)

Light source

50W halogen lamp (2000hours life), deuterium lamp (socket-type with 2000hours life)
Automatic position alignment is used for maximum sensitivity.

Monochromator

2 x 2 Grating-grating type double monochromator
Pre-monochromator: Concave diffraction grating monochromator  
Main monochromator: High performance blazed holographic grating in aberration-corrected Czerny-Turner mounting

Detectors

UV-VIS region: Photomultiplier R-928
NIR region: InGaAs and cooled PbS

Sample compartment

Inside dimensions: 150W x 260D x 140H (mm)

Dimensions

1020W x 660D x 275H (mm)

Weight

96 Kg

Ambient temperature

15 to 35°C

Ambient humidity

35 to 80% (no condensation, 70% or less at temperatures of 30°C or more)

Power requirements

AC 100V, 120V, 220V, 230V, 240V, 50/60Hz

Power consumption

300VA